Operation in Master-Slave mode:
To set a xture to slave-mode navigate to REMOTE. To activate the slave funciton press “EN-
TER” (keep it down) and press “ESC” in addtion. The display will show either REMOTE INACTIVE
if no DMX-signal is being received or REMOTE ACTIVE if a DMX-signal is being received. To lea-
ve this function press “ESC” (keep it down) and press “ENTER” in addition. Connect the P8 with
DMX cables. Select STANDALONE -> RUN with the master xture. Start function by pressing
“ENTER” (keep it down) and pressing “ESC” in addition. All connected xtures will repeat the
steps synchronized to the master xture. To leave the menu press “ESC” (keep it down) and press
“ENTER” in addition. If you realize that a xture reacts inaccurate check if the display shows
REMOTE ACTIVE.
5.7 INFO
The menu informs about the current software/rmware version. The non-resettable TOT
OPERATE TIME counter displays total hours of use since the P8 was manufactured.
Temperature readouts from the display panel (TEMP BASE LCD) and power supply unit (TEMP
BASE PS) in the base, as well as the drivers for red, green and blue (TEMP HEAD DRV R/G/B)
and the LED printet circuit board for red, green and blue (TEMP HEAD LED R/G/B) in the head
are available. In each case, you can view the current temperature and the maximum temperature
reached since the readout was last reset individually. The TEMP HEAD LEDs views the actual
temperature of the single LEDs.